CHAPTER 8 INTERFACE
8-1 CONTROL I/O
The Control I/O is intended for inputting/outputting weighing control signals to an external unit. It consists of 6 inputs and
8 outputs.
The capability of each input/output terminal can be selected, except COM (see 6-3, 6-4 for selection method).
Upon shipment, the Control I/O terminals were set for normal batching (Built-in Automatic Program Mode).
TERMINAL FUNCTIONS IN THE BUILT-IN AUTOMATIC PROGRAM MODE
Division
Terminal
No.
Function Name Description
A1 Zero
Clears the gross to zero. However, it does not function beyond the
range set with the calibration
A2 Tare Subtracting the tare weight and a displayed weight becomes the net.
A3 Batch start Starts the weighing sequence.
A4 Emergency stop
Stops charging or discharging and turns on the output terminal set for
the weighing sequence error.
A5 Discharge start Starts the discharging sequence.
Input
A6 Key enable
While this input is ON, the keys disabled by the general function
(FNC-01) are enabled.
A7 Input COM Input COM. Each input is accepted by shorting it with this terminal.
COM
A8 Output COM Output COM
B1 Zero band Turned on when the gross is lower than zero band setting.
B2 Underlimit Turned on when the judgment result is underlimit.
B3 Overlimit Turned on when the judgment result is overlimit.
B4 Full flow Turned on when the weighing sequence is full flow.
B5 Medium flow Turned on when the weighing sequence is medium flow.
B6 Dribble flow Turned on when the weighing sequence is dribble flow.
B7 Discharge Turned on during the discharging sequence.
Output
B8 Batch finish Turned on when the weighing sequence is completed and judged.
CONTROL I/O CONNECTOR, ACCESSORY
Parts Name Q'ty A&D’s parts Number Description
Connector
1 JI-361J016-AG
FCN361J016-AU (or AG),Fujitsu
Connector cover
1 JI-360C016-B
FCN360C016-B, Fujitsu