13. OP-03 RS-232C SERIAL INTERFACE
This interface allows the HC-i series to be connected with a multifunction printer or a
personal computer.
The OP-03 unit includes an interface board, a connector plug (DIN type) and two
screws. (M3x6 tapping type).
13-1. Installation
1. Disconnect the AC adapter from the scale. If the battery is used, switch off the
scale.
2. Loosen the screw and remove the panel covering the option slot.
3. Connect the connector cable on the OP-03 to the connector inside the option slot.
4. Fix the OP-03 unit using the two screws included in the OP-03.
13-2. RS-232C Specifications
Transmission form Asynchronous, bi-directional, half-duplex
Data format Baud rate: 2400, 4800, 9600 bps
Data: 7 bits + parity 1bit (even / odd) or 8 bits (non-parity)
Start bit: 1 bit
Stop bit: 1 bit
Code: ASCII
Terminator: Data Send / C
R
L
F
Data Receive / C
R
or C
R
L
F
LSB
0
1
2
3
4
5
MSB
6
Pin connections
2 Receive data
3 Transmit data
5 Signal ground
7 Data set ready
1, 4, 6 and 8 N.C.
O
p
tion slot
Screw
Interface
Sc
r
e
w
s
Stop
b
i
t
1 (-15V~-5V)
0 (5V~15V)
Start bit Data bit Parity bit
Inside of the HC-
i
(View from outside)
Mating connector: JA+TCP0586
(Included in the OP-03)
Zobrazit stránku 0
1 2 3 4 5 6 7 8 9 10

Shrnutí obsahu

Strany 1 - 13-2. RS-232C Specifications

4313. OP-03 RS-232C SERIAL INTERFACE This interface allows the HC-i series to be connected with a multifunction printer or a personal computer.  The

Strany 2 - 8f-06-02

52PF,‘ID~’,$CD,$CR,$LF,& $CR,$LF,& ‘Count’,$CR,$LF,& $SP4,$PC,$CR,$LF,& ‘Unit~Weight’,$CR,$LF,& $SP4,$UW,$CR,$LF,& ‘Weight’,$

Strany 3 - Example of f-06-02 settings

44 The HC-i is designated as DCE (Data Communication Equipment). 13-3. Data Output Mode  The Data Output Modes and Parameters are set by F-Function

Strany 4 - 13-6. Command Mode

45 Baud Rate (f-06-04) Select the baud rate according to the device to be connected.  2400 bps (f-06-04="0") Select 2400 bps to connect wi

Strany 5 - Command List

46 13-5. Connecting the AD-8121 Printer / MODE 3  When using MODE 3 of the AD-8121 printer, printouts are obtained using the PRINT key (f-06-01

Strany 6 - Data Format

47 Command List Command Definition Notes @ Start / stop continuous data transmission. A Same as RESET key. Key command D Set a known tare

Strany 7

48 If the command is S , T or Z , the scale will send a second acknowledgment <ACK><CR><LF> or <ACK> (see F-Funct

Strany 8

49  Unit Weight Command ? U W CLF Reply U W, + 1 . 234567[ [ gCLF U W, + 0 . 272531[ lbCLF  Total Count Command ? A Q CLF Reply A Q, + 0 0

Strany 9

50Reply ACKCLF ID Number: Maximum 6 digit Upper Limit: Maximum 9 digit including sign Lower Limit: Maximum 9 digit including sign  Re

Strany 10

5113-6. Using UFC (Universal Flex Coms) Function  The UFC function allows you to print out as you format the printer (UFC format).  The scale can s

Komentáře k této Příručce

Žádné komentáře