30
6-3 CONTROL I/O INPUT RELATED
INF-01: Capability of Input Terminal A1
INF-02 : Capability of Input Terminal A2
INF-03: Capability of Input Terminal A3
INF-04: Capability of Input Terminal A4
INF-05: Capability of Input Terminal A5
INF-06: Capability of Input Terminal A6
Setting
Default
Parameter Description
0 No capability
1 Zero
2 Tare
3 Batch start
4 Emergency stop
5 Discharge start
6 Key enable
7 Automatic free fall command
8 Disable thumbwheel switch read
9 Clear tare
10 Accumulation command
11 Cancel previous accumulation
12 Clear accumulation
13 Hold
1 2 3 4 5 6
14 Print command for manual print
6-4 CONTROL I/O OUTPUT RELATED
OUTF-01: Capability of Output Terminal B1
OUTF-02: Capability of Output Terminal B2
OUTF-03: Capability of Output Terminal B3
OUTF-04: Capability of Output Terminal B4
OUTF-05: Capability of Output Terminal B5
OUTF-06: Capability of Output Terminal B6
OUTF-07: Capability of Output Terminal B7
OUTF-08: Capability of Output Terminal B8
Setting
Default
Parameter Description
0 No capability
1 Zero range
2 Underlimit / (Hi-Hi)
3 Overlimit / (Hi)
4 Full flow / [Full] / (Go)
5 Medium flow / (Lo)
6 Dribble flow / (Lo-Lo)
[ ] Loss-in-weighing
( ) Check-weighing
7 Discharge gate open
8 Batch Finish
9 Stability
10 Online
11 Weighing sequence running
12 Weighing sequence error
13 Input acknowledge
14 Zero range error
15 Weighing capacity overflow
1 2 3 4 5 6 7 8
16 Low battery
INF-01 through INF-06 represents the input terminals A1 through A6, respectively. The content of setting is
common to each terminal
but initial settin
differs.
OUT-01 through OUT-08 represent the output terminals B1 through B8, respectively. The content of setting is
common to each terminal
but initial settin
differs.