A&D AD-4410 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Kuchyňské váhy A&D AD-4410. Brochure - A&D Company Ltd [en] Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 6
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
72
144
ZERO STABLE GROSS NET HOLD
(118.5)
(6)
67
137
100 - 240V
A&D Company ,Limited
50/60Hz 10VA
RS-232C C.L./OP
CONTROL I/O
LOAD CELL
AD-4410 WEIGHING INDICATOR
(181)
123
70
116
152
48
80
2-ø5
4-6 12
ZERO
0
TARE
T
Net/B/G
NET GROSS
ON
/
OFF
ESC
I
/
ENTER
F
External dimensions
Unit: mm
Rear panel
Panel cutout dimensions
68
+0.7
0
138
+1
0
Unit: mm
Stand dimensions
Compressor
High Performance Digital Filter
Analog unit
Input sensitivity
Zero adjustment range
Load cell excitation
Temperature coefficients
Nonlinearity
Input noise
Maximum measurement voltage
Input impedance
A/D conversion method
Internal resolution
Display resolution
Sampling rate
Calibration
Digital unit
Display elements
Measurement data display
Status display
Over 0.15µV/d (d=minimum division)
–35mV to +35mV (–7mV/V to +7mV/V)
DC5V±5%, 120mA
Remote sensing function included
Up to 8 load cells (350) can be connected
Zero; ±0.02µV/˚C (Typ.)
±0.1µV/˚C (Max.)
Span; ±3ppm/˚C (Typ.)
±15ppm/˚C (Max.)
0.005% of F.S.
Less than 0.3µVp-p
–35mV to +35mV (–7mV/V to +7mV/V)
Over 10M
Delta-sigma modulation
Approx. 16,000,000
999,999d (
less than 20,000d recommended
)
100 times/sec.
Actual load calibration or digital span
calibration not using actual load
Weighing display:
7-segment 6-digit green LED
Character height of 14.6mm
Polarity display: 1 green LED
Situational display: 6 red LEDs
Display switchable between net and
gross weight
Display range: 0 to 999,999d
(Select between 1, 2, 5, 10, and 50 for
minimum division “d”)
Units: Affix a “g”, “kg”, or “t” unit sticker
ZERO, STABLE, GROSS, NET, HOLD and
a light which can be given a custom
function by the user
External output components
Standard serial output (ch1)
Standard serial output (ch2)
Control I/O
Modbus-RTU
Basic specifications
Power source voltage
Power consumption
Operating temperature and humidity
Dimensions
Panel cut dimensions
Dust/water protection
Weight
Options
OP-03
OP-04
OP-11
Note: Only 1 OP-03 or OP-04 can be attached, when OP is attached 20mA
current loop will become unusable.
Standard accessories
Instruction manual, 7-pin DIN connector, 8-pin DIN connector,
load cell connector, power cable, rubber packing, capacity plate, unit stickers
Note: Please prepare an RS-232C connector for standard serial output (ch1).
A straight cable will be used when connecting to PC or PLC.
RS-232C 9-pin Dsub (male)
20mA current loop signal
(For connection with A&D peripherals)
3-point input function selection
(Non-voltage connection point or
open collector)
3-point output function selection
(open collector output)
Supported with RS-232C (included as
standard) or RS-232C/RS-485 (optional).
AC100V to 240V 50/60Hz
Approx. 10VA
–10˚C to 40˚C/85%RH or less
(Condensation must be avoided)
144(W) 72(H) 125(D) mm
(Protrusions included, cable excluded)
138 68 mm
The IP65 display when mounted into
a panel
(Using included rubber packing)
Approx. 800g
RS-485 (attached to ch2) DIN connector
RS-232C (attached to ch2) DIN connector
Stand
Specifications
A Weighing Indicator that Can Be Used in an Environment with Vibrations
Featuring the Newly Developed High-Performance Digital Filter (HPDF) for
Environments with Vibration Issues
The High-Performance Digital Filter provides high accuracy/high speed weighing in environments
with vibration problems.
The AD-4410 greatly reduces the costs and maintenance required for anti-vibration equipment
since it copes with vibrations without requiring many mechanical measures. What's more,
conducting weighing while applying vibrations, once an extremely difficult task, is now possible.
The High-Performance Digital Filter only requires one setting. For this reason, optimal settings for
v
ibration cancelling can be found after just a few tries.
Powerful Vibration Cancelling Feature
Until now, to conduct calibration, sources of vibration had to be completely stopped, or calibration
had to be conducted on weekends or holidays when machines are not active. However, even in an
environment with vibrations, the AD-4410 can be calibrated at any point, so costs incurred from
stopping production or calibrating on weekends or holidays will disappear.
Can be Calibrated in an Environment with Vibrations
Fast
response!
Even with
vibrations,
weighing is easy!
Reliably
accurate!
Vibration-Resistant Weighing Indicator
Powerful vibration-cancelling function
(High Performance Digital Filter)
High speed sampling (100 times/second)/high accuracy
Circuits equipped with powerful noise reduction
Accurate linear correction function using high-order
equations
Average holding function
Appearance and/or specifications subject to change for improvement without notice.
AD4410-ADCC-02-ZW2-13502
http://www.aandd.jp
…Clearly a Better Value
Zobrazit stránku 0
1 2 3 4 5 6

Shrnutí obsahu

Strany 1 - Compressor

72144ZERO STABLE GROSS NET HOLD(118.5)(6)67137100 - 240V A&D Company ,Limited50/60Hz 10VARS-232C C.L./OPCONTROL I/OLOAD CELLAD-4410 WEIGHING I

Strany 2 - Industry

Weighing while inducing vibrationWeighing while raising and loweringBody weight measurement of animals moving about vigorouslySimple checkweig

Strany 3

Weighing while inducing vibrationWeighing while raising and loweringBody weight measurement of animals moving about vigorouslySimple checkweig

Strany 4

Weighing while inducing vibrationWeighing while raising and loweringBody weight measurement of animals moving about vigorouslySimple checkweig

Strany 5

72144ZERO STABLE GROSS NET HOLD(118.5)(6)67137100 - 240V A&D Company ,Limited50/60Hz 10VARS-232C C.L./OPCONTROL I/OLOAD CELLAD-4410 WEIGHING I

Strany 6

72144ZERO STABLE GROSS NET HOLD(118.5)(6)67137100 - 240V A&D Company ,Limited50/60Hz 10VARS-232C C.L./OPCONTROL I/OLOAD CELLAD-4410 WEIGHING I

Komentáře k této Příručce

Žádné komentáře