A&D EJ-440 Specifikace

Procházejte online nebo si stáhněte Specifikace pro Kuchyňské váhy A&D EJ-440. A&D EJ-440 Product specifications Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1

1WMPD4002746B

Strany 2 - Compliance with FCC rules

8 4.3. Breeze Break The breeze break can prevent a measurement error due to a (disturbing) wind. Wipe it with a dry lint free cloth or a lint f

Strany 3 - CONTENTS

9 5. OPERATION 5.1. Turn The Power ON And OFF 1. Press the ON:OFF key to turn the power ON. All of the symbols are displayed as s

Strany 4

10 5.3. Units The most common unit of weight used around the world is the gram, but there is often a need to shift to alternative units specific

Strany 5 - UNPACKING

11 5.5. Basic Operation 1. Select a weighing unit. 2. When the display does not show zero, press the RE-ZERO key to set the display to zero.

Strany 6 - PART NAMES AND FUNCTIONS

12 5.7. Counting Mode (pcs) The balance weighs the sample pieces and calculates the unit weight. Using the sample unit weight, the scale counts

Strany 7

13 10. Counting accuracy is improved when the ACAI indicator turns off. Each time the above operation is performed, a more accurate unit weight wil

Strany 8 - SETTING UP

14 6. ACCUMULATION FUNCTION This function counts the number of times articles are weighed, calculates the total mass value and can display the n

Strany 9 - Power Source

15 Operations Selecting A Weighing Unit 1. Select a unit to be used in the accumulation function with pressing the UNITS key. The unit can

Strany 10 - Assembling the breeze break

16 7. CALIBRATION This function adjusts the balance for accurate weighing. Perform calibration in the following cases. When the balance is f

Strany 11 - OPERATION

17 7. end is displayed. Remove the weight from the pan. When the GLP output (function setting “info 1” or “info 2”) is selected, glp i

Strany 12 - 0.000

This Manual and Marks All safety messages are identified by the following, “WARNING” or “CAUTION”, of ANSI Z535.4 (American National Standard In

Strany 13 - 060.003

18 8. FUNCTIONS 8.1. Key Operation The ON:OFF key to cancel the operation and turns the balance off. Item key to select a class and an item. In

Strany 14 - Counting Mode (pcs)

19 8.3. Setting Example To set auto power-off function to “Enabled”, and the ACAI function to “Disabled”. 1. Press and hold the SAMPLE key

Strany 15 - 75.8

20 8.4. Storing Weighing Units It is possible to store the weighing units that will actually be used from the units available. For the units avai

Strany 16 - ACCUMULATION FUNCTION

21 8.5. Function List Class Item Param-eter Description  0 Auto power-off disabled poff Auto power-off 1 Auto power-off enabled Automaticall

Strany 17 - Operations

22 Class Item Param-eter Description  0 Water temperature ldin Liquid density input 1 Liquid density The way to input liquid density.  0 Not

Strany 18 - Calibration Using A Weight

23 9. OPTIONS The following options are available for the EJ-123/EJ-303 balance: EJ-02 USB interface EJ-03 RS-232C serial interface EJ-13

Strany 19

24 9.2. EJ-03 RS-232C Serial Interface The EJ-03 allows an EJ-123/EJ-303 balance to be connected with a printer or a personal computer with the R

Strany 20 - FUNCTIONS

25 Separator (“ ” shows a space.)Pin Connections D-Sub 9 pin male connector The interface is designated as DCE (Data Communication Equipm

Strany 21 - Setting Example

26 Data Output Mode Stream mode Set the function to “prt 0”. The balance outputs the current display data. The data-update rate is approximat

Strany 22 - Storing Weighing Units

27 9.4. EJ-13 Density Determination Kit Using this option and calculation program, the balance can determine the density (specific gravity) of a sa

Strany 23 - Function List

1 CONTENTS 1. INTRODUCTION...3 2.

Strany 24

28 Entering the density of a liquid (ldin = 0) 1. Press the UNITS key to select SG . 2. Press and hold the UNITS key to display the liq

Strany 25 - OPTIONS

29 Example of density measurement Selecting the density measurement mode 1. Press the UNITS key to select SG . The weighing unit is “g”.

Strany 26 - Interface Specifications

30 10. ID NUMBER AND GLP The ID number is used to identify the balance when Good Laboratory Practice (GLP) is used. The ID number is stored in

Strany 27 - , + 0 0 0 0 . 0 00 g C

31 10.2. GLP Report To print the GLP report, set the function to “info 1”, “pU5e 1” and set the AD-8121B printer to MODE 3. To output the GLP r

Strany 28 - Command Mode

32 Calibration Test Report The calibration test mode is used to compare a calibration test weight with the calibration test data weighed by the b

Strany 29 - Change the function table

33 AD-8121 format “info 1” General format “info 2” ~ : Space, ASCII 20h CR : Carriage return, ASCII 0Dh LF : Line feed, A

Strany 30 - t---25

34 “End Block” 3. Press and hold the PRINT key. Release the PRINT key when recend is displayed. The balance outputs the “End block”. 4.

Strany 31 - 8.008

35 11. MAINTENANCE 11.1. Notes On Maintenance Do not disassemble the balance. Contact your local A&D dealer if your balance needs service or

Strany 32 - Setting The ID Number

36 Note: Pressing the PRINT key without adding samples may reduce the counting accuracy. Starting from the 100 samples, 100 - may be displaye

Strany 33 - GLP Report

37 12. SPECIFICATIONS 12.1. Generals MODEL EJ-123 EJ-303 Weight capacity 120 g 310 g Minimum display “d” = digit 0.001 g 0.001 g Repeatability

Strany 34 - Calibration Test Report

2 12. SPECIFICATIONS...37 12.1. Genera

Strany 35 - 23.456

38 12.3. Options EJ-02 USB interface EJ-03 RS-232C serial interface EJ-13 Density determination kit 12.4. Dimensions Unit: mm

Strany 36 - recend

39 13. GRAVITY ACCELERATION MAP Values Of Gravity At Various Locations Amsterdam 9.813 m/s2 Manila 9.784 m/s2Athens 9.807 m/s2 Melbourne 9.800 m/

Strany 39 - SPECIFICATIONS

3-23-14 Higashi-Ikebukuro, Toshima-ku, Tokyo 170-0013, JAPAN Telephone: [81] (3) 5391-6132 Fax: [81] (3) 5391-6148 A&D ENGINEERING, INC.

Strany 40 - Dimensions

3 Protective film1. INTRODUCTION This manual describes how this balance works and how to get the most out of it in terms of performance. The EJ-1

Strany 41 - GRAVITY ACCELERATION MAP

4 3. PART NAMES AND FUNCTIONS Total indicator Measurement in air for specific gravity M+ indicator Measurement in water ACAI indicator

Strany 42 - World Map

5 Turns the power ON or OFF. Switches the weighing units and modes. Clears the display to zero (combined zero and tare). Held down to enter the

Strany 43

6 4. SETTING UP 4.1. Setting Up Your Balance 1. Place the weighing pan on the main unit. 2. Adjust the level of the balance using the leveling

Strany 44

7 4.2. Power Source For the power source, the AC adapter or 4 x “AA” size dry-cell batteries can be used. When Using The AC Adapter Use a stable